• Description

• Compact, mobile unit
• Works as single-stage, two-stage or two-stage intercooled compressor
• Independently controlled compressor units, both with variable-speed dynamometer drives
• Clear, fully-instrumented control panel with mimic diagram
• Low-noise footprint
• Completely fail-safe operation – interlocks and pressure-relief valves prevent misuse

Essential Services
Electrical supply:
220–240 VAC, 50/60 Hz 32 A phase to neutral or phase to
phase
Note: This equipment needs a high current electrical
supply.
Water supply (for the intercooler):
3.0 litres a minute
Operating Conditions
Operating environment:
Laboratory
Storage temperature range:
–25°C to +55°C (when packed for transport)
Operating temperature range:
+5°C to +40°C
Operating relative humidity range:
80% at temperatures < 31°C decreasing linearly to 50% at
40°C


Specifications
Nett dimensions and weight:
1200 mm x 660 mm x 1600 mm and 440 kg
Compressors:
Twin cylinders
Speed range 200-1000 rev.min–1
Maximum delivery pressure 10.3 bar